G620pt

Pan-Tilt Hydrocarbon/VOC OGI Camera

Product Variations

Monitor more of your site while reducing blind spots and trips into the field. The FLIR G620pt gives you continuous, automated monitoring across complex gas facilities, ensuring you catch potential leaks, verify them, and prioritize repairs before they become problems. This remotely controlled pan-tilt system sweeps across tanks, compressors, and process units, allowing the cooled optical gas imaging and integrated visual cameras to deliver the thermal and visible context teams need to tell a problem leak from routine venting. Purpose-built for FLIR ADGiLE deployments where hazardous rating solutions are not required, the G620pt turns round-the-clock surveillance into verifiable situational awareness and helps your team act with confidence instead of guesswork.

See Every Emission Event Across Your Entire Site
Remotely controlled pan-tilt movement with preset tours lets you use just one camera to monitor multiple areas and assets, maximizing coverage while controlling hardware and installation costs.
A high-sensitivity cooled thermal sensor plus integrated visual camera gives operators the full scene context for faster event assessment.
Feeds directly into the ADGiLE solution for intelligent, round-the-clock monitoring that helps teams distinguish potential leaks from routine venting. Alarms carry meaning so attention goes where it matters.

Specifications

Highlighted
IR Resolution 640 × 512 (327,680 pixels)
Focal Plane Array (FPA) - Effective pixels HOT MWIR T2SLS / 3.2–3.4 μm
Thermal Sensitivity/NETD <15 mK at 25°C
Spectral Range 3.2–3.4 µm
Imaging & Optical
Automatic Image Adjustment Linear, PE
Color Palettes Selectable 8-bit
Detector Pitch 15 µm
Detector Type High Operating Temperature (HOT) MWIR T2SLS
Digital image enhancement High Sensitivity Mode (HSM)
f-number f/1.59
Field of view (FOV) 14.5° lens: 14.4° × 11.5°
24° lens: 23.6° × 19°
Focal Length 14.5° lens: 38 mm
24° lens: 23 mm
Focal Plane Array (FPA) - Effective pixels HOT MWIR T2SLS / 3.2–3.4 μm
Focus Motorized
Full Frame Rate 30 Hz
Gas Sensitivity [NECL] CH₄: 16 ppm × m
Hydrocarbons (niabara gas mix): 6.4 ppm × m
NECL: ΔT 10°C, distance = 1 m
Image Frequency 30 Hz
Image Modes IR image, High Sensitivity Mode (HSM)
IR Resolution 640 × 512 (327,680 pixels)
Minimum Focus Distance 14.5° lens: 0.5 m (1.6 ft)
24° lens: 0.3 m (1.0 ft)
Noise Reduction Auto/manual
Non-radiometric IR video streaming H.264 or MJPEG over RTSP
Optical Zoom 30x optical, 8x digital (integrated Full HD visual camera)
Overlay RTSP only
Radiometric IR video recording GigE Vision
Radiometric IR video streaming GigE Vision
Sensor Cooling FLIR FL100 Linear cooler
Spectral Range 3.2–3.4 µm
Thermal Sensitivity/NETD <15 mK at 25°C
Zoom Digital zoom, 1x, 2x, 4x, 8x
Measurement & Analysis
Accuracy ≤100°C ±2°C, >100°C ±2% of reading
DC Voltage 24 VDC 2.5 A max (optional factory-fitted 100–240 VAC mains to 24 VDC PSU)
Object Temperature Range -10°C to 120°C (14°F to 248°F)
Communication & Data Storage
Command and Control GEV: Genicam; RTSP: Web Interface, REST API
Communication Interfaces Ethernet from camera module
Connector Direct connection via RJ45 CAT6A cables
Digital I/O connector type M12 12-pin A-coded, Male (shared with external power)
Digital Inputs 2x dry-contact, Vin(low) = 0–1.5 V, Vin(high) = 3–25 V
Digital Outputs 2x relay outputs, 0–48 VDC, max. 350 mA
Solid-state opto relay
1x dedicated as fault output (NC)
Encoding H.264 or MJPEG over RTSP streaming
Ethernet Communication ONVIF Ethernet to VMS or Web browser, internal telemetry control for visual camera zoom lens
Ethernet Connector Type RJ45
Ethernet Interface RJ45 (10/100/1000Base-Tx)
Ethernet Protocols IPv4/v6, TCP, UDP, IGMP(Multicast), ICMP, DHCP, HTTP, HTTPS, RTP, RTSP, FTP, SNMP, SMTP, UPnP, WS-Discovery, Zero Configuration, NTP, DDNS, RTMP
General
Weight 13.25 kg to 13.75 kg (29.2 lb to 30.3 lb) depending on camera/lens model
Power
Power Consumption 60 W max (nominal)
Environmental & Certifications
Certifications RoHS: 2011/65/EU
WEEE: 2012/19/EU
RED: 2014/53/EU
EMC: ETSI EN 301 489-1 (radio), ETSI EN 301 489-17, EN 55032 (emission), EN 55035 (immunity), EN 61000-4-8 Level 5 (magnetic field), EN 61000-6-2, Immunity Industrial Environment, FCC 47 CFR part 15 B, class B (emission), ICES-003
Directives EMC: 2014/30/EU, WEEE: 2012/19/EU
EMC ETSI EN 301 489-1 (radio), ETSI EN 301 489-17, EN 55032 (emission), EN 55035 (immunity), EN 61000-4-8 Level 5 (magnetic field), EN 61000-6-2, Immunity Industrial Environment, FCC 47 CFR part 15 B, class B (emission), ICES-003
Encapsulation IK10, IP66/IP67, NEMA 4X
Enclosure Material Aluminum
Hazardous Location Compliance Not applicable (non-ATEX configuration)
Mounting Wall bracket, pole/corner mount
Operating Temperature Range -20°C to 60°C (-4°F to 140°F) standard (-40°C option on request)

Resources & Support

Brochure

FLIR OGI Brochure (Optical Gas Imaging)

Export Restrictions

The information contained in this page pertains to products that may be subject to the International Traffic in Arms Regulations (ITAR) (22 C.F.R. Sections 120-130) or the Export Administration Regulations (EAR) (15 C.F.R. Sections 730-774) depending upon specifications for the final product; jurisdiction and classification will be provided upon request.